Preparation and imaging of intravascular high-frequency transducer

Xinlun Li, Xiaobing Li, Zheng Wu, Feifei Wang, Lixin Jiang, Junting Tian, Jiewen Zhou, Xiangyong Zhao

Abstract


Intravascular ultrasound (IVUS) imaging is by far the most favorable imaging modality for coronary artery evaluation. IVUS transducer design and fabrication, a key technology for intravascular ultrasound imaging, has a significant impact on the performance of the imaging results. Herein, a 35-MHz side-looking IVUS transducer probe was developed. With a small aperture of 0.40 mm × 0.40 mm, the transducer exhibited a very wide -6 dB bandwidth of 85% and a very low insertion loss of -12 dB. Further, the in vitro IVUS imaging of a porcine coronary artery was performed to clearly display the vessel wall structure while the corresponding color-coded graph was constructed successfully to distinguish necrotic core and fibrous plaque via image processing. The results demonstrated that the imaging performance of the optimized design transducer performs favorably.


Keywords


High-Frequency Ultrasound Transducer; Intravascular Ultrasound Imaging

Full Text:

PDF

Included Database


References


World Health Organization. Cardiovascular diseases (CVDs) [EB/OL]. (2017-05-17)[2022- 04-22].

Falk, E., Nakano, M., Bentzon, J. F., Finn, A. V., & Virmani, R. (2013). Update on acute coronary syndromes: the pathologists' view. European heart journal, 34(10), 719–728.

Tarkin, J.M.; Dweck, M.R.; Evans, N.R.; Takx, R.A.P .; Brown, A.J.; Tawakol, A.; Fayad, Z.A.; Rudd, J.H.F. Imaging atherosclerosis.Circ. Res. 2016, 118, 750–769.

de Feyter PJ, Serruys PW, Davies MJ, et al.Quantitative coronary angiography to measure progression and regression of coronary atherosclerosis. Value, limitations, and implications for clinical trials [J]. Circulation, 1991, 84(1): 412-423.

Joshi FR, Lindsay AC, Obaid DR, et al. Noninvasive imaging of atherosclerosis [J]. European Heart Journal - Cardiovascular Imaging, 2012, 13(3): 205-218.

Garcìa-Garcìa, H.M.; Gogas, B.D.; Serruys, P.W.; Bruining, N. IVUS-based imaging modalities for tissue characterization:Similarities and differences. Int. J. Cardiovasc. Imaging 2011, 27, 215–224.

Erglis, A.; Jegere, S.; Narbute, I. Intravascular ultrasound-based imaging modalities for tissue characterisation. Interv. Cardiol. Rev.2014, 9, 151.

K. Jansen, G. van Soest, A.F. van der Steen, Intravascular PhotoacousticImaging: A New Tool for Vulnerable Plaque Identification, Ultrasoundin Medicine and Biology, 2014.

Elliott MR, Thrush AJ. Measurement of Resolution in Intravascular Ultrasound Images. Physiological Measurement. Nov,1996.

Brezinski ME, Tearney GJ, Weissman NJ, Boppart SA, Bouma BE, HeeMR, Weyman AE, Swanson EA, Southern JF, Fujimoto JG, Assessing Atherosclerotic Plaque Morphology: Comparison of Optical Coherence Tomography and High-Frequency Intravascular Ultrasound. Heart. May,1997.

Li, X.; Wu, W.; Chung, Y .; Shih, W.Y .; Shih, W.-H.; Zhou, Q.; Shung, K.K. 80-MHz intravascular ultrasound transducer using PMN-PT free-standing film. IEEE T rans. Ultrason. Ferroelectr. Freq. Control 2011, 58, 2281–2288.

Ma X, Cao W, Single-Crystal High-Frequency Intravascular Ultrasound Transducer With 40-mu m Axial Resolution, Ieee Transactions on Ultrasonics Ferroelectrics and Frequency Control, 67 (2020) 810-816.

Zhu B, Zhang Z, Ma T, Yang X, Li Y, Shung KK, Zhou Q, (100)-Textured KNN-based thick film with enhanced piezoelectric property for intravascular ultrasound imaging, Appl. Phys. Lett., 106 (2015).

Wang JS, Chen MZ, Zhao XY, et al. Fabricationand high acoustic performance of high frequency needle ultrasound transducer with PMN-PT/Epoxy 1-3 piezoelectric composite prepared by dice and fill method [J]. Sensors and Actuators A: Physical,2021, 318: 112528.

Xu J, Han ZL, Wang NH, et al. Micromachined high frequency 1-3 piezocomposite transducer using picosecond laser [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,2021, 68(6): 2219-2226.

Krimholtz R, Leedom DA, Matthaei CL, New equivalent circuits for elementary piezoelectric transducers, Electronics Letters, 6 (1970) 398-399.

Athanasiou, LS, et al. IEEE Transactions on Information Technology in Biomedicine 16(3): 391-400. (2012).

K. r. Erikson, r. a. Banjavic, and P. l. carson. J. Ultrasound Med. 1, 1 (1981).

Fei, C.; Yang, Y .; Guo, F.; Lin, P .; Chen, Q.; Zhou, Q.; Sun, L. PMN-PT single crystal ultrasonic transducer with half-concave geometric design for IVUS imaging. IEEE T rans. Biomed. Eng. 2017, 65, 2087–2092.

Peng, J.; Ma, L.; Li, X.; Tang, H.; Li, Y.; Chen, S. A novel synchronous micro motor for intravascular ultrasound imaging. IEEE T rans. Biomed. Eng. 2018, 66, 802–809.

Zhou QF, Lau ST, Wu DW, Shung KK, Prog. Mater. Sci. 56, 139 (2011).

Melzer S, Ankri R, Fixler D, Tarnok A, Nanoparticle uptake by macrophages in vulnerable plaques for atherosclerosis diagnosis, J. Biophotonics, 8 (2015) 871-883.




DOI: https://doi.org/10.18686/esta.v9i4.272

Refbacks

  • There are currently no refbacks.


Copyright (c) 2023 Xinlun Li

Creative Commons License