Junction Temperature Consistency Analysis of MMC Submodule
Abstract
Although modular multilevel converter(MMC)is currently widely used in the field of DC power transmission due to its excellent topology performance, the natural DC bias characteristics inevitably cause thermal imbalance of internal devices. Too high temperature at the junction of power devices is one of the major causes of damage. Therefore, it is necessary to further investigate the factors that affect the device junction temperature. This paper calculated the power loss and junction temperature by combined the thermal impedance model and compared junction temperature under two typical modulation strategies .
Keywords
Full Text:
PDFReferences
Adabi ME, Martinez-Velasco JA., Alepuz S. Modeling and simulation of a MMC-based solid-state transformer. Electric Energy, 2018; 100: 375–387.
Yang L, Zhao C, Yang X. Loss calculation method of modular multilevel HVDC converters. In: Electrical Power and Energy Conference. Winnipeg. 2011; pp. 97–101.
Wu Cong, M., Avenas, Y., Miscevic, M., Wang, M.X., Mitova, R., Lavieville, J.P., Lasserre,P. (2014) Thermal analysis of a submodule for modular multilevel converters. In: Applied Power Electronics Conference and Exposition. Fort Worth. pp. 2675-2681.
DOI: https://doi.org/10.18686/esta.v8i1.175
Refbacks
- There are currently no refbacks.
Copyright (c) 2021 Zhuo Chen, Yumei Guo, Xiangming Wang
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.