Study on Comprehensive Evaluation of Elevator Door System Based on AHP-CRTIC

Wenjiao Zai, Kai Yang

Abstract


The elevator door system is affected by the physical structure, external factors and geographical location and other factors, and has become the most prone to failure and accident components in the eight elevator systems. Select 15 evaluation factors including speed, acceleration, operating noise, vibration frequency and response time in the transmission system; voltage, current, corrosive gas, conductive dust in the safety protection system, engagement depth, leveling accuracy, temperature, humidity, balance coefficient and load weight in the stripping system, calculate the subjective and objective weight of each evaluation factor by AHP and CRTIC evaluation method, establish the AHP-CRTIC comprehensive evaluation model. Compared with the evaluation results of AHP, C RTIC and AHP-CRITIC models in the actual elevator system, the results show that the evaluation accuracy of combined empowerment is the highest, which provides a new idea and method for the safety performance evaluation of the elevator door system.


Keywords


Elevator Door System; Evaluation Factor; AHP Hierarchy Analysis Method; CRTIC Objective Empowerment Method; Comprehensive Evaluation

Full Text:

PDF

Included Database


References


Xu Y. Influence of PLC technology on the development and application of elevator ladder group control system [J]. Technology Vision, 2022, No.391(25):22-24.

Yu FG, Li TT, Wang MK, etc. Discussion on the elevator safety risk factors [J]. Special Equipment Safety Technology, 2022, No.248(05):46-48.

Meng L, Wang XY, Guo QL. Study on common problems of elevator door system inspection [J]. Engineering and technology research, 2020,5(06):269-270.

Ma LJ. Common safety protection devices and detection problems of the elevator door system [J]. Modern Property (China), 2019, No.472(10):24.

Li ZW, Meng LH, Sun KL. Discussion on the safety control principles in the case that the elevator door is accidentally opened [J]. Elevator in China, 2018, 29 (07): 7-9 + 12.

Wang LL. Discussion on the grounding fault protection problem of the elevator safety circuit [J]. Special Equipment Safety Technology, 2023, No.251(02):41-42.




DOI: https://doi.org/10.18686/esta.v10i5.550

Refbacks

  • There are currently no refbacks.


Copyright (c) 2023 Wenjiao Zai, Kai Yang

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.